Cooling system HYDRIVE
The cooling system is most often used to discharge liquefied and gaseous fuels. It has a compact design that allows easy mounting on the chassis. It is made of stainless steel. The system is driven by a piston pump - type "Banana" - 80 l.
It is used in systems where there is a sharp and long-term rise in the hydraulic oil temperature. It is characterized by 10kW thermal scattering. This maintains the correct temperature of the oil and guarantees long operation with the system. In this way, all the prerequisites for overheating of the oil are switched off and no working shutdown is necessary.
By the operation of the cooling system, the hydraulic oil life is extended.
System efficiency:
- oil flow rate: 55-100l / min
- working pressure: 50-300bar
- fan speed: 2800 rpm
- return pressure: 1-5bar
- 10kW thermal dispersion at ambient temperature of 40 ° C
- flow rate of the hydraulic motor of the fan: 5,5l / min
- weight without oil: 24kg
- tank capacity: 10l